| Availability: | |
|---|---|
| Quantity: | |
VS-PE
Volsun
VS-PE PE overhead line cover is made from radiation crosslinked polyolefin material and designed for insulation protection of bare overhead conductors. It provides excellent electrical insulation, tracking resistance, weather resistance, anti-aging performance and mechanical strength, making it suitable for overhead power line protection in outdoor environments.
The product can be used continuously from -50°C to +125°C and offers convenient installation without heating or flame. With a locking groove structure, the cover can be installed over bare conductors to improve insulation protection and reduce construction time. Special sizes or colors are available upon request.
| Item | Value |
|---|---|
| Product Model | VS-PE |
| Product Type | PE overhead line cover for bare conductor |
| Material | Radiation crosslinked polyolefin |
| Application | Insulation protection for bare overhead conductors |
| Voltage Range | ≤10kV / ≥35kV |
| Continuous Operating Temperature | -50°C to +125°C |
| Installation Method | No heating or flame required |
| Key Properties | Insulation, tracking resistance, weather resistance, anti-aging, mechanical protection |
| Available Sizes | Φ14 / Φ18 / Φ28 / Φ38 |
| Standard Structure | Locking groove design |
| Customization | Special sizes or colors available upon request |
Electrical insulation protection: Designed to cover bare overhead conductors and improve insulation protection.
Weather resistant material: Made from radiation crosslinked polyolefin for outdoor power line applications.
Wide temperature performance: Suitable for continuous use from -50°C to +125°C.
High strength and wear resistance: Provides mechanical protection for overhead conductors.
Anti-aging and corrosion resistance: Supports long-term outdoor service in demanding environments.
No heat installation: Can be installed without flame, heating or heat-shrink equipment.
Shorter construction time: Simple installation helps reduce power outage construction time.
Multiple voltage options: Available for ≤10kV and ≥35kV applications.
Custom options: Special sizes or colors are available upon request.
Item | Test method | ≤10kV | ≥35kV |
Tensile strength | GB1040 | ≥12MPa | |
Elongation at break | GB1040 | ≥400% | |
Tensile Strength Change | GB7141/120℃,168hrs | ±20% | |
Rate of change of elongation at break | GB7141/120℃,168hrs | ±20% | |
Breakdown strength | GB1408 | ≥20kV/mm | ≥25kV/mm |
Volume resistivity | GB1410 | ≥1×1013Ω·cm | |
Copper corrosion | ASTMD 2671,120℃,168hrs | No Corrosion | |
Low temperature flexibility | ASTMD 2671,-40℃,4hrs | ||
Size | Voltage (KV) | Conductor Section ( mm2) | Max Conductor O.D.(mm) | Remark |
≤10KV | ||||
Ф14 | 0.38-10 | ≤70 mm2 | 14mm | No sealant in the lock groove |
Ф18 | 0.38-10 | ≤150 mm2 | 18mm | No sealant in the lock groove |
Ф28 | 0.38-10 | 185-240 mm2 | 28mm | No sealant in the lock groove |
Ф38 | 0.38-10 | 300-800 mm2 | 40mm | No sealant in the lock groove |
≥35KV | ||||
Ф14 | 0.38-10 | ≤70 mm2 | 14mm | With sealant in the locking groove |
Ф18 | 0.38-10 | ≤150 mm2 | 18mm | With sealant in the locking groove |
Ф28 | 0.38-10 | 185-240 mm2 | 28mm | With sealant in the locking groove |
Ф38 | 0.38-10 | 300-800 mm2 | 40mm | With sealant in the locking groove |
Remark: Special sizes or colors are available on request.
VS-PE is designed for insulation and protection of bare conductors in overhead power line systems, especially where weather resistance, electrical insulation and fast installation are required.
Typical applications include:
Bare overhead conductor insulation protection
Outdoor overhead power line covering
Electrical insulation for exposed conductor sections
Protection of conductors in areas requiring weather-resistant insulation
Power line maintenance and retrofit projects
Short-duration outage construction where fast installation is required
Selecting the correct PE overhead line cover model is important for safe and reliable insulation protection. Before selection, measure the outside diameter of the bare conductor and choose a cover size with an inner diameter that matches the conductor size.
The inner diameter of the overhead line cover should be slightly larger than the conductor diameter to support smooth installation and future maintenance. For higher voltage applications, select the corresponding model with sealant in the locking groove.
Confirm the conductor outside diameter and select the correct VS-PE cover size.
Clean the conductor surface and remove dust, oil or other contaminants if necessary.
Open the locking groove and position the cover over the bare conductor section.
Press the cover into place along the conductor length until the locking groove is fully closed.
For models with sealant in the locking groove, make sure the groove is properly closed to support sealing performance.
Check that the cover is fully seated and provides continuous insulation coverage over the required area.
VS-PE provides a fast, heat-free solution for bare conductor insulation protection in overhead power line systems. Its radiation crosslinked polyolefin material delivers weather resistance, electrical insulation, anti-aging performance and mechanical protection. With multiple sizes and voltage options available, VS-PE helps improve installation efficiency and supports reliable outdoor conductor protection.
VS-PE is used for insulation protection of bare overhead conductors in outdoor power line systems.
VS-PE is made from radiation crosslinked polyolefin material, providing electrical insulation, weather resistance and mechanical protection.
No. VS-PE can be installed without heating, flame or heat-shrink equipment, helping reduce installation time.
VS-PE can be used continuously from -50°C to +125°C.
VS-PE is available in Φ14, Φ18, Φ28 and Φ38 sizes for different conductor outside diameters.
The ≤10kV version is supplied without sealant in the locking groove, while the ≥35kV version is supplied with sealant in the locking groove for enhanced sealing and insulation protection.
Measure the outside diameter of the bare conductor and choose a cover size that is slightly larger than the conductor diameter to support installation and future maintenance.
Yes. Special sizes or colors are available upon request.