MPRS-10KV bus bar heat-shrink tubing is an ideal choice for safeguarding copper busbars within electrical cabinets, providing exceptional insulation protection. Busbar heat shrinkable sleeves boast remarkable attributes such as UV resistance, tear resistance, and longevity, guaranteeing enduring performance and utmost safety.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
  • MPRS-10KV

  • VOLSUN

Description

Busbar heat shrink tubing is a protective material used for busbar and cable connections in power systems. It is made of thermally shrinkable polyolefin materials that can shrink and tightly encapsulate the surface of busbars or cables when heated, providing insulation and protection. Busbar heat shrink sleeving has excellent insulating properties and can effectively prevent electrical leakage and short circuits in electrical equipment. It is easy to install, requiring only a heat gun or similar tool to heat and quickly shrink and secure onto busbars or cables.

Volsun 10KV bus bar heat-shrinkable tube are perfect for insulation protection of copper busbar in electrical cabinets. They main include feature UV resistance, tear resistance, and aging resistance, ensuring long-lasting performance and safety. 

Various sizes and colors are available to meet customer requirements, ensuring optimal protection and performance.


Features

  • Heat shrink ratio: 2:1

  • Low smoke, soft, high strength, resistance to electric carbon marks

  • Shrinking temperature: 84℃ ~ 120℃

  • Operating temperature: -55℃ ~ 125℃

  • Environmental protection standard: RoHS

  • Standard color: red, yellow, green, other colors can be customized


Technical Performance

Item

Typical   data

Test   standard

Tensile   Strength

≥8.0MPa

ASTM D 2671

Elongation   at Break

≥300%

ASTM D 2671

Tensile strength after thermal aging

≥6.9MPa

130℃×168h

Elongation at break after thermal aging

≥100%

130℃×168h

Axial rate of change

-8%~+8%

ASTM D 2671

Thermal shock

No cracks

JB 7829 Appendix D

Breakdown strength

≥20kV/mm

ASTM D 149

Hardness (Shore A)

≤90

GB2411

Volume   resistivity

≥1014Ω.cm

IEC 60093


Dimensions

Size(mm)

Supplied ID(mm)

Flattening width(mm)

Wall thickness before shrink(mm)

Full recovered size(mm)

Standard packing

(m/roll)

Inside diameter

Wall thickness

Φ16

18.0±2.0

28±3

0.85±0.3

≤9.0

1.5±0.3

25

Φ20

22.0±2.0

35±3

0.85±0.3

≤11.0

1.5±0.3

25

Φ25

25.5±2.0

40±3

0.9±0.3

≤13.0

1.7±0.3

25

Φ30

31.5±3.0

50±4

0.9±0.3

≤16.0

1.75±0.3

25

Φ40

41.0±3.0

65±4

0.9±0.3

≤21.0

1.75±0.3

25

Φ50

51.0±3.0

80±4

0.95±0.3

≤26.0

1.8±0.3

25

Φ60

61.0±3.0

96±5

1.0±0.3

≤31.0

2.0±0.3

25

Φ65

63.5±3.0

100±5

1.0±0.3

≤33.0

2.0±0.3

25

Φ70

70.0±3.0

110±5

1.0±0.3

≤36.0

2.0±0.3

25

Φ80

80.0±3.0

125±5

1.0±0.3

≤42.0

2.0±0.3

25

Φ90

90.0±3.0

143±5

1.0±0.3

≤47.0

2.0±0.3

25

Φ100

100.0±4.0

158±5

1.1±0.4

≤55.0

2.1±0.3

25

Φ120

120.0±4.0

188±5

1.1±0.4

≤65.0

2.2±0.3

25

Φ150

150.0±4.0

234±5

1.2±0.4

≤80.0

2.3±0.4

25

Φ180

180.0±4.0

280±5

1.4±0.4

≤95.0

2.5±0.4

25


Note: Special size and packaging can be customized upon request.


FAQ :


1. What is the primary application of bus bar heat shrink tube?

A: Bus bar heat-shrinkable tubes are primarily used for insulating protection of copper bars in electrical cabinets.


2. Can bus bar heat-shrinkable tubes be customized in terms of size and color?

A: Yes, they can be customized to meet customer requirements, ensuring a perfect fit and aesthetic appeal.


3. How do I apply bus bar heat-shrinkable tubes to the copper bars?

A: The tubes are heated to a certain temperature, causing them to shrink and tightly fit around the copper bars for effective insulation.


4. Are bus bar heat-shrinkable tubes resistant to chemicals and solvents?

A: They are generally resistant to chemicals and solvents commonly encountered in electrical cabinets, providing added durability.


5. Can bus bar heat-shrinkable tubes be used for insulation in outdoor applications?

A: Yes, they can be used for insulation in outdoor applications due to their UV resistance, ensuring longevity even when exposed to sunlight.


Related News

content is empty!

Subscribe To Our Newsletter

China's pioneer manufacturer of cold shrink tube,fiberglass sleeve, heat shrink tube,identification sleeve---Volsun

QUICK LINKS

PRODUCTS

CONTACT INFO

  +86-13776247502
  +86-512-66386808
  No.402, Mudong Road, Mudu Town, Wuzhong District, Suzhou City,215101, Jiangsu Province, China
Leave a Message
Contact Us
Copyright ©️ 2023 Volsun Group. Technology by leadong.com. Sitemap.